1×1 tDCS

The most trusted and validated device in tDCS upgraded with LTE and Adaptive Current to 5 mA

The 1×1 tDCS was developed to precisely provide all tDCS research and clinical protocols. Pioneering and pivotal tDCS trials have relied on the 1×1 platform, which stands out for simple set-up and programming, intuitive controls, and seamless integration with best-in-class tDCS accessories. Unique features allow you to focus on the subject and experiment, not the device. The 1×1 tDCS is the standard for precise and reproducible tDCS.

Product Features

Description

Industry Standard For Clinical Trials. Apply Standard tDCS Protocols, Establish New Ones.

Current intensity from 0.1 to 5 mA, and current duration from 5 to 40 minutes. Higher current performance is made possible by unique accessories, integrated LTE and Adaptive current ramp. The 1×1 tDCS is capable of delivering higher tolerated doses than any other system. At conventional tDCS doses, such as 1 mA and 2 mA, the 1×1 tDCS provides the most tolerated stimulation, which means studies using the 1×1 tDCS also have the best compliance and most reliable sham performance.

 

Stimulation precision and control

The Soterix Medical 1×1 platform is the most accurate tDCS technology available. Built into every 1×1 device are the most advanced monitoring and control systems updating performance and feedback over 1000 times per second. Stimulation output fidelity (signal-to-noise) is maintained during the entire stimulation session even if electrode conditions change. Precise control of output waveform is essential for stimulation efficacy and safety.

 

Simple to use Open-Panel™

With a simple press of a button to set stimulation duration and intensity, and back-lit status displays visible in dim or bright room light, the Soterix Medical Open-Panel™ design takes the guess work out of the stimulation.

 

Validated High Intensity Stimulator™

The 1×1 tDCS system is the only validated device for high-intensity applications.

 

Device Features

Designed to simply set-up, provide intelligent warning of a fault condition, and allow for adjustments for patient comfort, these features facilitate reliable and tolerated tDCS. The Soterix Medical SmartScan™ feature is central in all tDCS devices to allow reliable set-up and monitoring. The RELAX™, Tickle™, and TrueCurrent™ innovations were developed for the 1×1 tDCS.

Technical Specifications

Electrical and Operating Characteristics:

  • Power source: 2, 9V Li-Ion (600 mAh) rechargeable batteries (removable)
  • Battery life (on full charge): 6 hrs
  • Adjustable Current Intensity: up to 5,000 µA
  • Adjustable Duration: up to 40 minutes
  • Length: 7.91 in.
  • Width: 5.9 in.
  • Height: 2.83 in.
  • Connector type: shielded banana
  • Maximum Output Voltage: 40V ± 5%

Downloads

Applications:

  • 1×1 tDCS system is the only validated device for high-intensity applications
  • transcranial Direct Current Stimulation (tDCS)
  • tDCS research
  • treatments focused on neuropsychiatric and neurological disorders and rehabilitation

1×1 tDCS

Device Features

Related Products

The only electrodes validated for HD stimulation.

Are you interested in our products?

Please feel free to contact us if you need any other information
Contact Us