SynAmps RT
64 Channel amplifier
Product Features
Description
Utilizing the latest technology, SynAmps RT allows for discrete monopolar and bipolar channels, enhancing the flexibility of recordings. Additional high level inputs are isolated to allow voltage level signals to be merged with the physiological data. Linking headboxes together allows more than 500 channels to be recorded. A 64-channel SynAmps RT EEG system has one headbox, with 70 channels in total. A fully isolated, programmable bipolar excitation supply is also provided capable of supplying up to +/- 10VDC at 100mA to external bridges or measurement devices.
Maximum Sampling Rate: 20,000 Per Channel all channels driven
Faster sampling rates allow for more accurate sampling of the analog data being recorded. Signals such as Auditory Brain Stem Response require these faster rates, while typical ERP measures benefit from increased resolution.
Sampling Method: All Channels Sampled Simultaneously
Current technology eliminates the problems associated with sample and hold circuits. Utilizing a dedicated 24-bit A to D chip for each channel, the SynAmps RT enhances resolution and accuracy of each sample by ensuring a more valid measure of the data without decay or skew. The 24-bit resolution allows for even the most subtle differences in amplitude to be measured accurately.
Recording Bandwidth: DC to 3500 Hz
Many slow potentials (i.e., P300, MMN, CNV) have components that can only be measured accurately using a DC amplifier. DC amplifiers are also not subject to the AC coupled, filter time constant that distorts recordings after an artifact. The high frequency end of the SynAmps RT’s range allows for more accurate recording of the fastest frequencies.
Active Noise Cancellation: Utilizing advanced driven reference technology
SynAmps RT sets a new standard for amplifier design, both in terms of safety and signal quality. Actively sampling environmental noise, and applying an antiphase signal to eliminate that noise, elevates the CMRR to unprecedented levels. This technology also provides increased patient protection.
Recording in fMRI Environments: Integration with the Micro MagLink RT System
The same amplifier that is used in standard recording environments can also be used to record EEG data in the MRI by interfacing to the Micro MagLink RT system. SynAmps RT was built with enough input range and accuracy to sample both the EEG and the fMRI artifact with sufficient resolution to remove the artifact and ensure the EEG is left intact.
>10 G Ohm Input Impedance: Allows standard impedance or fast preparation to be obtained
SynAmps RT allows you to choose on a subject by subject basis to prepare the scalp electrode impedance to the scientifically accepted levels or to record with high impedance, due to time or subject constraints. This flexibility allows you the option to maximize your data collection for each subject and collect the best data the situation allows.
Portability and Integration: Small Package, big features
Digital amplifiers are typically small and thus portable, but portability also means unpredictable environmental noise. SynAmps RT has built in technology to function even in the worst electromagnetic fields. Custom solutions such as Mu metal shielding are available to ensure data quality even under hostile conditions.
Specifications
- Max Number of Channels: 70
- EEG Channels: 64
- Bipolar Channels: 4
- Analog Inputs (HLI): 2
- DC/AC: DC, AC (2 modes)
- Max Sampling Rate: 20 kHz
- Sampling Rate (Hz): 100, 200, 250,
- 500, 1000, 1250, 2000, 2500, 5000, 10000, 20000
- Bandwidth: DC-3500 Hz
- Resolution: 24-bit
- Input Range: 400 mV (DC mode), 1.9 mV (AC mode)
- Sensitivity: 24 nV (DC mode), 3 nV (AC mode)
- Input Impedance: >10 GOhm Common Mode Rejection (CMRR): >110 dB
- Noise (peak-to-peak): <0.5 uV (DC mode)
- Impedance Check: Yes
- Trigger: 16-bit TTL
- TMS Compatible: Yes
- tACS/tDCS Compatible: Yes
- fMRI Compatible: Yes, in combination with the Micro Maglink system
- MEG Compatible: Yes, in combination with the Micro Maglink system
- Device Synchronization: A maximum of four headboxes can be connected to a single system unit and allow recording of multiple subjects; one subject per headbox, maximum four per system unit, 2 system units can be combined to allow for 512 channels total or 8 subjects.
- External clock Sync: Yes, optional via IMECSU
- Headcap Connector: Yes
- Recording Interface: USB
- Power: Isolation Transformer
Downloads
Applications:
- Research EEG
- EEG
- High Density EEG
- Evoked Potentials (EP)
- Event-Related Potentials (ERP)
- BAEP/ABR
- EEG & fMRI
- EEG & MEG
- EEG & tACS
- EEG & tDCS
- EEG & TMS
Related Products
Are you interested in our products?
Please feel free to contact us if you need any other information Contact UsNEUROLOGY RESEARCH – NEUROSCAN
EEG Amplifiers
SynAmps RT
Neuvo
Grael 4K EEG
Siesta Wireless
EEG/ERP/EP Software
CURRY – Data Acquisition/Analysis
Stimulation
STIM 2
fMRI/EEG and MEG/EEG Recording
MicroMagLink RT
MEG:
Orion
NEUROLOGY DIAGNOSTICS – COMPUMEDICS NEUROSCIENCE
Clinical EEG Amplifiers
Grael 4K PSG-EEG
Grael 4K EEG
Grael LT-EEG
Neuvo LTM-EEG
Siesta 802-EEG
Software
Profusion EEG
Profusion neXus 360
Profusion neXus LMS
Profusion neXus Scheduler
Persyst Software
HD Digital Video
SLEEP DIAGNOSTICS– COMPUMEDICS SLEEP
PSG Amplifiers
Grael 4K PSG-EEG
Grael 4K PSG
Somté PSG
Somté
Siesta 802
Software
Profusion Sleep
Profusion neXus 360
Profusion neXus LMS
Profusion neXus Scheduler
Somté software
HD Digital Video
Profusion Plus
ECG Free
SENSORY ANALYZERS (QST) & ADVANCED PAIN STIMULATORS– MEDOC
Pathway
TSA 2
Q-Sense
Q-Sense CPM
Q-Sense fMRI System
AlgoMed
VSA 3000
TRANSCRANIAL DOPPLER (TDC) SYSTEMS– RIMED
Digi-Lite™
Digi-Lite™ IP
Digi-One™ Portable
Probe Holder LMY-3™
NIRS & DRY ELECTRODE TECHNOLOGY– WEARABLE SENSING
NIRS
DSI-Hybrid-EEG+fNIR
Dry EEG Systems
DSI 24
DSI VR300
DSI 7
DSI 7 Flex
DSI 4
Dry EEG Wireless TriggerHub
Software
DSI Streamer
Q-States
EMG/EP & NCS SYSTEMS– EMS BIOMEDICAL